Downpipe & telescopic tube & flex arm
Downpipe 3/4" primed and galvanized
The downpipe is intended for use in sprinkler systems (stationary water extinguishing systems). The downpipe enables quick and easy installation of sprinkler heads. The installation position is vertical (for standing or suspended sprinklers) or horizontal (side wall sprinklers).
The downpipe is designed to supply only one sprinkler head. The downpipe is available with reduction on one or both sides, in lengths of 300 mm, 500 mm, 600 mm, 800 mm and 1,000 mm (special lengths on request) and pipe diameter 3/4” (26.9 mm). The sprinkler connections are Rp 3/8“ and Rp 1/2” (internal pipe thread). The downpipe is made of pipe in accordance with EN 10255, surface primed red-brown or galvanized.
Approvals: VdS / FM applicable
Catalog: Section 3.1
Downpipe 1" primed and galvanized
The downpipe is intended for use in sprinkler systems (stationary water extinguishing systems). The downpipe enables quick and easy installation of sprinkler heads. The installation position is vertical (for standing or suspended sprinklers) or horizontal (side wall sprinklers).
The downpipe is designed to supply only one sprinkler head. The downpipe is available with a reduction on one or both sides, in lengths of 300 mm, 500 mm, 600 mm, 800 mm and 1,000 mm (special lengths on request) and a pipe diameter of 1” (33.7 mm). The sprinkler connections are Rp 3/8“, Rp 1/2” and Rp 3/4” (internal pipe thread). The downpipe is made of pipe in accordance with EN 10255, surface primed red-brown or galvanized.
Approvals: VdS / FM applicable
Catalog: Section 3.1
Telescopic tube, type VS
The telescopic tube VS is intended for use in sprinkler systems (stationary water extinguishing systems). The telescopic tube VS is adjustable in length and therefore enables the sprinkler heads to be adapted quickly and easily, e.g. to the suspended ceiling. The installation position is vertical (suspended sprinklers) or horizontal (side wall sprinklers). Surface KTL-coated (black).
The telescopic tube VS is designed to supply only one sprinkler head. The telescopic tube VS has an external thread R1“ (line side) and internal thread Rp 3/8” - 1/2” (sprinkler side). The length adjustment is 50 mm / 60 mm / 100 mm. The VS telescopic pipes are available in lengths of 90 - 140 mm / 100 - 160 mm / 140 - 240 mm / 220 - 320 mm / 300 - 400 mm. Length adjustment under pressure is possible.
Approvals: VdS / FM
Catalog: Section 3.2
Telescopic tube, type VS (3/4")
The telescopic pipe VS (3/4") is intended for use in sprinkler systems (stationary water extinguishing systems). The telescopic pipe VS (3/4") is adjustable in length and therefore enables the sprinkler heads to be adapted quickly and easily, e.g. to the suspended ceiling. The installation position is vertical (suspended sprinklers) or horizontal (side wall sprinklers). Surface KTL-coated (black).
The telescopic tube VS (3/4") is designed to supply only one sprinkler head. The telescopic tube VS (3/4“) has an external thread R1” (line side) and an internal thread Rp 3/4” (sprinkler side). The length adjustment is 60 mm / 100 mm. The telescopic pipes VS (3/4") are available in lengths of 140 - 200 mm / 180 - 280 mm. Length adjustment under pressure is possible.
Approvals: VdS/FM
Catalog: Section 3.3
Telescopic tube, type VSI
The telescopic tube VSI is intended for use in sprinkler systems (stationary water extinguishing systems). The telescopic tube VSI is adjustable in length and therefore enables the sprinkler heads to be adapted quickly and easily, e.g. to the suspended ceiling. The installation position is vertical (suspended sprinklers) or horizontal (side wall sprinklers). Surface KTL-coated (black).
The telescopic tube VSI is designed to supply only one sprinkler head. The telescopic tube VSI has an internal thread Rp1“ (line side) and an internal thread Rp 3/8” - 1/2” (sprinkler side). The length adjustment is 60 mm / 100 mm. The VSI telescopic pipes are available in lengths of 130 - 190 mm / 170 - 270 mm. Length adjustment under pressure is possible.
Approvals: VdS/FM
Catalog: Section 3.4
Telescopic tube, type VSN
The VSN telescopic tube is intended for use in sprinkler systems (stationary water extinguishing systems). The VSN telescopic tube is adjustable in length and therefore enables the sprinkler heads to be adapted quickly and easily, e.g. to the suspended ceiling. The installation position is vertical (suspended sprinklers) or horizontal (side wall sprinklers). Surface KTL-coated (black).
The VSN telescopic tube is designed to supply only one sprinkler head. The VSN telescopic tube has an external thread of R1“ (line side) and an internal thread Rp 3/8” - 1/2” (sprinkler side). The length adjustment is 100 mm. The VSN telescopic pipes are available in lengths of 420 - 520 mm / 990 - 1,090 mm. Length adjustment under pressure is possible.
Approvals: VdS/FM
Catalog: Section 3.5
Flexarm®, type FL1
The Flexarm®, type FL1 is intended for use in sprinkler systems (stationary water extinguishing systems). The Flexarm®, type FL1 is adjustable in length and therefore enables simple and quick horizontal adjustment of the angle in conjunction with e.g. telescopic pipes or downpipes. The installation position is above the pipe run. Galvanized surface.
The Flexarm®, type FL1 has an external thread R1“ (on the line side) and an internal thread Rp1” (on the sprinkler side). The horizontal length adjustment takes place in a radius of 360 mm. Positioning under pressure is possible.
Approvals: VdS/FM
Catalog: Section 3.6
Flexarm®, type FL2
The Flexarm® FL2 is intended for use in sprinkler systems (stationary water extinguishing systems). The Flexarm® FL2 is length-adjustable and therefore enables simple and quick horizontal adjustment of the angle in conjunction with e.g. telescopic pipes or downpipes. The installation position is underneath the service pipe. Galvanized surface.
The Flexarm® FL2 has an external thread R1“ (on the line side) and an internal thread Rp1” (on the sprinkler side). The horizontal length adjustment takes place in a radius of 360 mm. Positioning under pressure is possible.
Approvals: VdS/FM
Catalog: Section 3.7
“Your questions, our service”
If you have any questions about our product range, please contact our customer service. You are welcome to use our contact form to send us your inquiries. Our team will respond quickly to queries regarding availability, prices or technical details. Of course, you can also contact us by telephone or e-mail.
We will do our best to provide you with the information you need quickly and comprehensively.